3. Setting parameters
Firmware Requirement
Version: update to the latest version.
Support Mavlink v2 protocol
Set up the telemetry baud rate
Zio connects to FC at the baud rate of 115200. In case of connecting Zio to FC at any telemetry, note the telemetry setting at the corresponding baud rate. Example for telemetry 2:
MAV_1_CONFIG: “TELEM 2”
SER_TEL2_BAUD: “115200 8N1"
MAV_1_FORWARD: "1"
Set mount params
MNT_MODE_IN: “RC”
MNT_MODE_OUT: “Unknown: 2”
MNT_RC_IN_MODE: “1”
MNT_MAN_PITCH: “AUX3” // PAN/TILT choose axis
MNT_MAN_ROLL: “AUX2” // Zooming, High: Zoom in, Neutral: Stop, Low: Zoom out (current: only using mode control by angle)
MNT_MAN_YAW: “AUX1” // PAN/TILT move
COM_RC_IN_MODE: “Unknown: 3”
Set RC map channels
RC_MAP_AUX1: “Channel 6” // set channel 6 to AUX1 (Yaw)
RC_MAP_AUX2: “Channel 7” // set channel 7 to AUX2 (Roll)
RC_MAP_AUX3: “Channel 8” // set channel 8 to AUX3 (Pitch)
Last updated