Environmental Factors
Environmental Factors – Orus-L
This section allows you to configure environmental parameters to improve the accuracy of thermal measurements based on real-world conditions.
Atmospheric Temperature (K)
Range: 100 to 500 Kelvin Set the ambient air temperature for thermal compensation.
Distance (m)
Range: 0 to 255 meters Enter the distance between the Orus-L and the target object to enhance thermal accuracy.
Emissivity Target (%)
Range: 0% to 100% Defines the emissivity of the target surface.
⚠️ Default for most organic materials is around 95%.
Humidity (%)
Range: 0% to 100% Input the relative humidity of the environment, which may affect thermal readings.
ModifyB / ModifyK
Range: 0 to 255 (each) Advanced calibration parameters used for fine-tuning thermal correction models.
Only modify if you have specific calibration requirements or guidance.
Window Reflect Temperature (K)
Range: 100 to 500 Kelvin Temperature of the window or lens surface through which the sensor observes the target.
Temperature Unit
Choose your preferred unit for displaying temperature:
Celsius (°C)
Fahrenheit (°F)
Kelvin (K)
Saving Your Settings
Click “APPLY” to save and activate the new environmental configuration. Settings will be used to refine thermal imaging calculations in real time.